PROCESS AREA - STRUCTURE SE1

The SE1 structure, made by steel, consist of three main independent structures and described as follow:
  • 1st Body - pipe rack: The maximum height is about 9,2m and the plan dimensions are about 10,0mx19,5m. The gravity loads, due to 3 piping levels, have been supported by 3 transversal frames, which have also the task to guarantee the transversal stability against wind and seismic loads. In longitudinal direction the horizontal stability is guarantee by vertical bracings.
  • 2nd Body - pipe rack: The maximum height is about 9,2m and the plan dimensions are about 12,0mx20,5m. The gravity loads, due to 3 piping levels, have been supported by 3 transversal frames, which have also the task to guarantee the transversal stability against wind and seismic loads. In longitudinal direction the horizontal stability is guarantee by vertical bracings.
  • 3rd Body - Shelter: The maximum height is about 23,0m and the plan dimensions are about 36,0mx18,0m. The gravity loads, due to the crane and one service platform, have been supported by 7 main transversal frames, which have also the task to guarantee the transversal stability against wind and seismic loads. In longitudinal direction the horizontal stability is guarantee by vertical bracings.